タイトル:COSEL電源ノイズフィルター2025カタログ
- ページ
- 332/918
COSEL電源ノイズフィルター2025カタログ の332ページ目の概要です。
各ボタンで、目的のページを開いてください。
COSEL電源ノイズフィルター2025カタログ の332ページ目の概要です。
各ボタンで、目的のページを開いてください。
COSEL株式会社の 電源ノイズ フィルター 2025 カタログです。
RAC-DC Power Supplies Medical TypeUMA30FOrdering informationUM A 30 F -O -O1 2 3 4 5 61 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *7E : IEC Class IIT : Terminal blockSN : with Chassis & coverY : with PotentiometerC : with CoatingUMA*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELUMA30F-5UMA30F-12UMA30F-15UMA30F-24UMA30F-36UMA30F-48MAX OUTPUT WATTAGE[W]15303031.230.631.2DC OUTPUT5V 3A12V 2.5A15V 2A24V 1.3A36V 0.85A48V 0.65ASPECIFICATIONSMODELUMA30F-5UMA30F-12UMA30F-15UMA30F-24UMA30F-36UMA30F-48VOLTAGE[V]AC85 - 264 1fCURRENT[A]FREQUENCY[Hz]50/60 (47-63)INPUTEFFICIENCY[%]INRUSH CURRENT[A]LEAKAGE CURRENT[uA] ACIN 264V200maxTOUCH CURRENT[uA] ACIN 264V75maxVOLTAGE[V]51215243648CURRENT[A]32.521.30.850.65WATTAGE[W]15303031.230.631.2LINE REGULATION[mV]*120max48max60max96max144max192maxLOAD REGULATION[mV]*1100max120max120max150max240max240maxRIPPLE NOISE [mVp-p] *2 lo=100%150 (Bandwidth 20MHz)OUTPUTTEMPERATURE REGULATION[mV]0~+50C 100max120max150max240max360max480maxSTART-UP TIME[ms]ACIN 115VACIN 230V40typHOLD-UP TIME[ms]OUTPUT VOLTAGE ADJUSTMENT RANGE[V]Fixed ("Y"option is available for adjusting output voltage between±10%)OUTPUT VOLTAGE SETTING[V]4.90 to 5.3011.50 to 12.5014.40 to 15.6023.00 to 25.0034.50 to 37.5046.00 to 50.00PROTECTIONOVERCURRENT PROTECTION [A]Works over 105% of rating and recovers automaticallyCIRCUIT AND OTHERS OVERVOLTAGE PROTECTION[V]5.75 to 7.0013.80 to 16.8017.25 to 21.0027.60 to 33.6041.40 to 50.4055.20 to 67.20INPUT-OUTPUTAC4,000V 1minute, DC500V 100MΩmin(At Room Temperature)2MOPPISOLATIONINPUT-FGAC2,000V 1minute, DC500V 100MΩmin(At Room Temperature)1MOPPOUTPUT-FGAC2,000V 1minute, DC500V 100MΩmin(At Room Temperature)1MOPPOPERATING TEMP.,HUMID. *3-20 to +70C, 20 - 90%RH(Non condensing)ENVIRONMENTIMPACT196.1m/s 2(20G), 11ms, once each X, Y and Z axisSAFETY ANDEMCOTHERSAGENCY APPROVALSANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL(equivalent to CAN/CSA-C22.2 No.60601-1),UL62368-1, EN62368-1, C-UL(equivalent to CAN/CSA-C22.2 No.62368-1), Complies with IEC60335-1EMC EMISSIONComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B, FCC Part 18-BEMC IMMUNITYComplies with EN61000-4-2, 3, 4, 5, 6, 8, 11HARMONIC ATTENUATOR*4Complies with IEC61000-3-2(Class A)No built-in active PFCCASE SIZE/WEIGHT*550.8X21.7X76.2mm [2.0X0.85X3.0 inches](WXHXD)/ 80g max(with Chassis and cover : 130g max)COOLING METHODConvectionWARRANTY WARRANTY *6 5 years(subject to the operating conditions)*1 Consult us about dynamic load and input response. Measure the output voltage by using theaverage mode of the tester to deal with the burst operation at low (Io=0~20%typ) load.*2 This is the result of measurement of the testing board with capacitors of 47μF and 0.1μFplaced at 150 mm from the output terminals by a 20MHz oscilloscope or a ripple-noisemeter equivalent to Keisoku-GikenRM104.When the load factor is low (Io=0~20%typ), the switching power loss is reduced by burstoperation, which will cause ripple noise to go beyond the specifications.*3 Output power derating is required. Refer to "Derating"*4 Please contact us about another class. When two or more units are operating it may notcomply with the IEC61000-3-2. Please contact us for details.*5 Dimensions below PCB are not included.*6 Consult us about details.*7 The listed options may affect the published standard specifications. Please contact us fordetailed product specifications and safety approvals.* All parameters not specially mentioned are measured at ACIN 230V, rated load and 25℃of ambient temperature.* Do not use the power supply in overcurrent conditions or in unspecified input voltageranges. Otherwise the internal components may be damaged.* Parallel operation is not possible with this model.* Acoustic noise may be heard from the power supply when used for pulse load.UMA-2August 29, 2025UMA-2 ? 330 ?