タイトル:COSEL電源ノイズフィルター2025カタログ

ページ
142/918

COSEL電源ノイズフィルター2025カタログ の142ページ目の概要です。

各ボタンで、目的のページを開いてください。

概要

COSEL株式会社の 電源ノイズ フィルター 2025 カタログです。

UMCSRAC-DC Power Supplies Medical TypeUMCS60FOrdering informationUMC S 60 F -O -O1 2 3 4 5 61 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5T : Terminal block*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELUMCS60F-5-EUMCS60F-12-EUMCS60F-24-EUMCS60F-48-EMAX OUTPUT WATTAGE[W]30546060DC OUTPUT5V 6A12V 4.5A24V 2.5A48V 1.25ASPECIFICATIONSMODELUMCS60F-5-EUMCS60F-12-EUMCS60F-24-EUMCS60F-48-EVOLTAGE[V]AC85 - 264 1fCURRENT[A]FREQUENCY[Hz]50/60 (47-63)INPUTEFFICIENCY[%]INRUSH CURRENT[A]LEAKAGE CURRENT[uA] ACIN 264V200maxTOUCH CURRENT[uA] ACIN 264V75maxVOLTAGE[V]5122448CURRENT[A]64.52.51.25WATTAGE[W]30546060LINE REGULATION[mV]*120max48max96max192maxLOAD REGULATION[mV]*1100max120max150max240maxOUTPUTRIPPLE NOISE [mVp-p] *2 lo=100% 150 (Bandwidth 20MHz)TEMPERATURE REGULATION[mV] 0~+40C 100max 120max 240max 480maxSTART-UP TIME[ms]ACIN 115VACIN 230V40typHOLD-UP TIME[ms]OUTPUT VOLTAGE SETTING[V]4.90 to 5.3011.50 to 12.5023.00 to 25.0046.00 to 50.00PROTECTIONOVERCURRENT PROTECTION [A]Works over 105% of rating and recovers automaticallyCIRCUIT AND OTHERS OVERVOLTAGE PROTECTION[V]5.75 to 7.0013.80 to 16.8027.60 to 33.6055.20 to 67.20ISOLATIONINPUT-OUTPUTAC4,000V 1minute, DC500V 100MΩmin(At Room Temperature)2MOPPOPERATING TEMP.,HUMID. *3-20 to +70C, 20 - 90%RH(Non condensing)ENVIRONMENTIMPACT196.1m/s 2(20G), 11ms, once each X, Y and Z axisSAFETY ANDEMCOTHERSAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1, ANSI/AAMI ES60601-1, C-UL (equivalentto CAN/CSA-C22.2 No.60601-1), EN60601-1 3rd, Complies with IEC60335-1EMC EMISSONComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B, FCC Part 18-BEMC EMMUNITYComplies with EN61000-4-2, 3, 4, 5, 6, 8, 11HARMONIC ATTENUATOR*6Complies with IEC61000-3-2(Class A)No built-in active PFCCASE SIZE/WEIGHT55.9X35.7X109.2mm [2.2X1.4X4.3 inches](WXHXD)/ 230g maxCOOLING METHODConvectionWARRANTY WARRANTY *4 5 years(subject to the operating conditions)ClassⅡ*1 Consult us about dynamic load and input response. Measure the output voltage by using theaverage mode of the tester to deal with the burst operation at low (Io=0~20%typ) load.*2 This is the result of measurement of the testing board with capacitors of 47μF and 0.1μFplaced at 150 mm from the output terminals by a 20MHz oscilloscope or a ripple-noisemeter equivalent to Keisoku-GikenRM104.When the load factor is low (Io=0~20%typ), the switching power loss is reduced by burstoperation, which will cause ripple noise to go beyond the specifications.*3 Output power derating is required. Refer to "Derating"*4 Consult us about details.*5 The listed option may affect the published standard specifications. Please contact us fordetailed product specifications and safety approvals.*6 Please contact us about another class. When two or more units are operating it may notcomply with the IEC61000-3-2. Please contact us for details.* All parameters not specially mentioned are measured at ACIN 230V, rated load and 25℃of ambient temperature.* Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.Otherwise the internal components may be damaged.* Parallel operation is not possible with this model.* Acoustic noise may be heard from the power supply when used for pulse load.UMCS-4August 29, 2025UMCS-4 ? 140 ?